ABSTRACT
Aim:
The aim of this study was to compare dosimetric advantages of using intensity-modulated radiation therapy (IMRT) and simultaneous-boost (SIB-IMRT) techniques for glioblastoma multiform (GBM).
Materials and Methods:
Ten patients with GBM were retrospectively selected between the years of 2020 and 2021. For all patients, two treatment plans were created. The plans were calculated using anisotropic analytical algorithm with 6 MV photon energy. Treatment doses were 50 Gy for planned target volume (PTV) (50 Gy), 10 Gy for PTV (60 Gy) and 60 Gy for PTV (60 Gy), which is planned as 2 Gy per daily fraction in IMRT technique. In the SIB-IMRT technique, which provides different dose levels in target volumes simultaneously in 25-day fractions, was used. All plans were compared with respect to the doses received by PTV and the organ at risk including brain system, optic chiasma, optic nerves, eyes, the dose homogeneity index (HI), conformity indexes (CI) and total monitor unit counts required for the treatment.
Results:
The average doses for PTV were 60.62±0.33 Gy for the IMRT technique and 60.58±0.32 Gy for the SIB-IMRT technique. The average doses for PTV, for both techniques were found to be similar. The average HI value for PTV (60 Gy) was 0.05±0.009 in IMRT, 0.13±0.197 in SIB-IMRT, 0.97±0.02 in IMRT, and 0.35±0.06 in SIB-IMRT, respectively. As a result of the statistical comparison, a significant difference was observed in HI and CI values between IMRT and SIB-IMRT in the analysis of the values of PTV (p=0.004, p=0.001). When the SIB-IMRT plans were compared with the IMRT plans, it was observed that the mean doses received by critical organs such as optic chiasma, optic nerve, and eye were significantly decreased in the SIB-IMRT technique (p=0.000).
Conclusion:
When the IMRT technique for GBM treatment was compared with the SIB-IMRT technique, SIB-IMRT provided better protection for organ at risk. SIB-YART plans may be clinically acceptable treatment modalities for GBM cancers.
INTRODUCTION
Glial tumors are the most common primary malignant brain tumors in adults1. Malignant gliomas (World Health Organization grade 3-4) constitute more than half of primary brain tumors, and approximately 75% of them are glioblastoma multiform (GBM) with grade IV2,3. It is known that malignant brain tumors, especially GBM, have lower survival rates and the worst prognosis due to their high progression potential4. The primary standard treatment for GBM treatment is surgery5,6. However, due to its high infiltrative character, GBM has high local recurrence rates even with the best surgical approach, which necessitates additional local treatments such as radiotherapy (RT). According to the results of phase III randomized studies, the standard adjuvant treatment of GBM is 60 Gy local RT ± alkylating agent-based chemotherapy7. In GBM RT, tumors can usually be located in or very close to critical radiation-sensitive structures such as the brain stem, optic chiasm, right optic nerve, left optic nerve, right orbit, and left orbit. The tolerance doses of these critical structures are lower than the targeted treatment doses, and this may cause damage to critical structures.
The aim in RT is to protect the critical structures around it in the best possible way, while giving the desired dose to the determined target volume8. Today, there are many RT options used in treatment. One of the most commonly used treatments in RT is intensity modulated RT (IMRT). In IMRT treatment techniques, the aim of treatment is determined in advance with the inverse planning system. In the optimization processes, it is tried to obtain a homogeneous and desired dose distribution in order to achieve these goals. In IMRT techniques, different fraction schemes can be applied to different target volumes simultaneously with the simultaneous integrated boost (SIB) method. In IMRT treatments for this purpose, organs at risk (OAR) and target volumes are displayed in three dimensions, and the most appropriate gantry angles and number of fields are determined, and treatment planning is made.
In this study, it was aimed to compare the current treatment plan of our patients with malignant glial tumors, who were treated with the IMRT technique, with the virtually created SIB-IMRT technique, dosimetrically.
GİRİŞ
Glial tümörler yetişkinlerde en sık görülen primer malign beyin tümörleridir1. Primer beyin tümörlerinin yarıdan çoğunu malign gliomlar (Dünya Sağlık Örgütü grade 3-4) oluşturmaktadır ve bunların da yaklaşık %75’i grade IV olan glioblastoma multiformdur (GBM)2,3. Malign beyin tümörlerinin, özellikle GBM’nin, yüksek progresyon potansiyeli nedeniyle, daha düşük sağkalım oranlarına ve en kötü prognoza sahip olduğu bilinmektedir4. GBM tedavisinin öncelikli olarak standart tedavisi cerrahidir5,6. Ancak GBM, yüksek infiltratif karakteri gereği en iyi cerrahi yaklaşımla bile yüksek lokal yineleme oranlarına sahiptir ki, bu da radyoterapi (RT) gibi ek lokal tedavilerin gerekliliğini ortaya koymaktadır. Faz III randomize çalışmaların sonuçlarına göre GBM’nin standart adjuvan tedavisi 60 Gy lokal RT ± alkilleyici ajan bazlı kemoterapidir7. GBM RT’de tümörler genellikle beyin sapı, optik kiazma, sağ optik sinir, sol optik sinir, sağ orbita ve sol orbita gibi radyasyona duyarlı kritik yapıların çevresinde veya çok yakınında olabilir. Bu kritik yapıların tolerans dozları, hedeflenen tedavi dozlarından daha düşüktür ve bu durum kritik yapıların zarar görmesine sebep olabilir.
RT’de amaç, belirlenen hedef hacme istenilen tüm doz verilirken, çevresindeki kritik yapıları en iyi şekilde korumaktır8. Günümüzde tedavide kullanılan çok sayıda RT seçeneği bulunmaktadır. RT’de en yaygın olarak kullanılan tedavilerden birisi de yoğunluk ayarlı RT’dir (YART). YART tedavi tekniklerinde invers planlama sistemi ile tedavi amacı önceden belirlenir. Optimizasyon işlemlerinde bu amaçları sağlamak için homojen ve istenilen doz dağılımı elde edilmeye çalışılır. YART tekniklerinde eş zamanlı ek doz simultane entegre (SIB) yöntemi ile farklı hedef hacimlere aynı anda farklı fraksiyon şemaları uygulanabilir. Bu amaca yönelik YART tedavilerinde risk altındaki organlar (RAO) ve hedef hacimler üç boyutlu görüntülenerek en uygun gantri açıları, alan sayıları belirlenir ve tedavi planlaması yapılır.
Bu çalışmada YART tekniği ile tedavi edilen malign glial tümörlü olgularımızın mevcut tedavi planının sanal olarak oluşturulmuş SIB-YART tekniği ile dozimetrik olarak karşılaştırılması amaçlanmıştır.
MATERIALS AND METHODS
Patient Selection
For the study, 10 patients with malignant glial tumors who were treated with 60 Gy RT and CRT in the Department of Radiation Oncology, Faculty of Medicine Selçuk University between 2020 and 2021 were selected. Permission for this study was obtained from the Ethics Committee of Selçuk University Faculty of Medicine, with the decision dated 07 April 2021 and numbered 2021/198. The clinical and dosimetric characteristics of the patients selected for the study are given in Table 1.
Target Volume and Critical Organs
All patients were immobilized with a head and neck thermoplastic mask in the supine position. The images obtained by scanning 3 mm slice thickness over the area of interest in the computed tomography (CT) unit were transferred to the treatment planning system (Eclipse, version 15.1; Varian). Preoperative and postoperative axial T1 contrast and axial T2-FLAIR magnetic resonance (MR) images were fused to the planning CT image set for contouring. For gross tumor volume (GTV) determination, T1 contrast-enhanced and axial T2-FLAIR from preoperative MR images or the cavity and surrounding area of contrast on postoperative MR were defined as GTV50.
The clinical target volume (CTV) CTV50 was created by adding an isometric 2-2.5 cm margin to the GTV50 to achieve the CTV, and the PTV50 was created by adding a 0.5 cm margin around the CTV50 for the planned target volume (PTV) definition. For the boost area, the GTV60 was contoured using preoperative MR axial T1 contrast-enhanced images. The CTV60 was created by adding an isometric 2-2.5 cm margin to the GTV60 and PTV60 was created by adding 0.5 cm margin around the CTV609,10. Brain stem, optic chiasm, right optic nerve, left optic nerve, right orbit and left orbita were contoured as critical organs. Target structures were removed with a 1 mm margin from each other in order to ensure sharp dose changes easily. By removing the parts of critical organs that intersected with the tumor with a margin of 2 mm, the mean dose values were reduced. The IMRT treatment technique was planned as PTV50, 50 Gy from 2 Gy/25 fractions in phase 1, and then 60 Gy in total from PTV60 2 Gy/5 fractions in phase 2. In the SIB-IMRT treatment technique, PTV60 was planned to be 2.4 Gy in 25 fractions.
Treatment Planning
In this study, the Varian Millennium 80-leaf collimators (Varian) treatment device available in our clinic was used. Dynamic IMRT and SIB-IMART treatment plans with 5 coplanar fields were created for GBM patients with IMRT and SIB-IMART techniques. IMRT plans were prepared with the inverse planning method using 6 MV X-rays. After the treatment plans were created, the optimization process was started. During the optimization process, minimum and maximum dose limitations were made to the target volumes, and it was aimed that 95% of the PTVs would receive 100% of the defined dose. Necessary dose limitations were made in order to give the lowest dose among the determined criteria to the organs at risk. Anisotropic Analytical Algorithm (v.15.1) was used for dose optimization and calculations of IMRT plans.
Plan Evaluation
Dose volume histograms (DVH) were used to compare the target volume and critical organ doses of the treatment plans. PTV and the doses taken by the OAR were evaluated by comparing DVHs from IMRT and SIB-IMRT plans. Homogeneity index (HI) and conformity index (CI) parameters are used to evaluate plans in different treatment options. The dose HI formula was defined according to the International Commission on Radiation Units report no: 8311.
It is defined in the formula as “D2 is the dose received by 2% of the target, D98 is the dose received by 98% of the target, and D50 is the dose received by 50% of the target”. In cases where CI is equal to 1, we can talk about the ideal dose distribution. If CI is greater than 1, the irradiated volume is greater than the target volume, and if CI is less than 1, the target volume is partially irradiated. The CI index is used to estimate the degree of suitability of the plan12. It is calculated as the ratio of the volume of PTV receiving 98% of the dose to the total volume of PTV. This value was calculated automatically with the planning option. By using DVHs, Dmax(Gy), Dmean(Gy) (maximum and mean doses at target volume), D98, D95, D50, and D2 data of PTV were compared. Dmax(Gy) and Dmean(Gy) values were compared for optic nerves, brain stem, optic chiasm and orbits in critical organs. In addition, the monitor unit (MU) values of the plans were compared.
Statistical Analysis
Statistical analysis was performed using the Statistical Package for Social Sciences version 25.1. The Paired samples t-test was used for statistical analysis of the difference between the two groups. A p value of <0.05 was considered statistically significant.
RESULTS
In Table 2, the mean of dose values of PTV60 and PTV50 obtained from IMRT and SIB-IMRT treatment plans, the mean of HI and CI values, and the mean numerical values for MU values, and the results of binary statistical analysis between techniques for 10 GBM patients are given. IMRT plans are more advantageous than SIB-IMRT plans in terms of covering the PTV60 target volume with the defined dose. The comparison of the plans showing the dose covering 95% of the targeted volume in IMRT and SIB-IMRT techniques is shown in Figure 1. It was observed that similar results were obtained in IMRT and SIB-IMRT plans in terms of covering the PTV50 target volume with the defined dose. Since the ideal value of HI was “0”, the plans with the most homogeneous dose distribution were found in the IMRT technique (p=0.004). Since the ideal value of CI was “1”, the most conformal technique was also found in the IMRT technique (p=0.001). The comparison of dosimetric values between techniques for critical organs is given in Table 3. When SIB-IMRT plans were compared with IMRT plans, the mean doses received by the brain stem, optic chiasm, optic nerves, and eyes were found to be significantly lower in the SIB-IMRT technique (p values: 0.006, 0.000, 0.000 and 0.000, respectively). In addition, the maximum doses received by the brain stem, optic chiasm, optic nerves and orbits were significantly reduced by the SIB-IMRT technique (p values: 0.000, 0.002, 0.000 and 0.000, respectively). The DVH of a patient whose treatment plan was prepared with IMRT and SIB-IMART is shown in Figure 2. The mean MU counts for the IMRT and SIB-IMRT techniques were 501±31 and 860±111, respectively. The MU value required for the IMRT technique was found to be significantly lower than for the SIB-IMRT technique (p=0.000).
DISCUSSION
Currently, the standard treatment for GBM tumors is surgery, chemoradiotherapy and adjuvant chemotherapy13. In high-grade astrocytomas, no matter how extensively the tumor tissue is surgically removed, the neoplastic cells at the microscopic level reproduce in the normal brain tissue due to their infiltrative structure. Therefore, RT is recommended to prevent the increase of residual cells or to eliminate the macroscopic tumor remaining after subtotal resection14. RT is an important treatment option in the treatment of malignant glial tumors. In this study, IMRT and SIB-IMRT plans were made for 10 cases diagnosed with malignant glial tumors, and they were compared dosimetrically in terms of target volume coverage, risky organ doses and MU.
Fogliata et al.15 evaluated the potential benefits of IMRT and SIB-IMRT plans in head and neck patients in terms of planning and at a dosimetric level. Dose distributions were obtained with inverse planning IMRT for all plans and sliding window technique was used after IMRT optimization. They stated that the physical dose distribution and homogeneity were better for the plans obtained with the IMRT technique. They found that the V95 parameter was lower in SIB plans (p=0.002). They stated that the doses received by organs at risk, such as the spinal cord and parotid, were lower in the SIB-IMRT technique. Similarly, in our study, it was found that the plans obtained with the IMRT technique were more advantageous in terms of dose coverage, but the doses received by the OAR were lower in the SIB-IMRT technique.
Li et al.16 compared IMRT and SIB-IMRT plans to deliver high doses to the prostate and lower doses to the pelvic region. They noted that the SIB-YART technique had potential advantages, including better preservation of critical structures, more efficient administration, shorter treatment time, and better biological efficacy. In parallel with this study, in this study conducted on 10 cases with a diagnosis of malignant glial tumor, it was observed that the mean doses received by the brain stem, optic chiasm, optic nerves and orbits were significantly lower in the SIB-IMRT technique when SIB-IMRT plans were compared with IMRT plans.
Onal et al.17 compared sequential boost (SEB) technique and SIB techniques dosimetrically in volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT). In their study, they stated that the SIB technique protects the heart better than the SEB technique in HT plans. In our study, it was observed that critical organs were better protected with the SIB technique.
Farzin et al.18 compared the SIB and SEB method for VMAT in 20 patients with high-grade gliomas. In their study, in the SIB method, PTV received 54 Gy in 30 fractions with a dose of 1.8 Gy per fraction, while the tumor bed received 60 Gy from 2 Gy per fraction. According to their results, they found that both techniques were similar in terms of target coverage, but the SIB technique was significantly superior in protecting critical organs. The results obtained from this study were found to be similar to our study.
Nageeti et al.19 compared the dosimetric coverage of PTV and OAR with SIB and SEB method in VMAT technique for 7 patients with a diagnosis of high-grade glioma. They stated in their study that although the protection of critical organs was similar for all plans, the use of SIB with fewer fractions of the total dose might be the best option for the treatment of patients with short survival without increasing toxicity. Contrary to this study, in our study, it was shown that the SIB-IMRT technique was more advantageous than IMRT plans because it protects critical structures at risk, and it provides a dosimetric advantage over IMRT plans because it protects healthy tissues.
In their study, Çelen and Kızılkaya20 aimed to dosimetrically compare PTV and OAR with sequential IMRT and SIB-IMRT techniques to the entire breast and boost area in patients who underwent breast-conserving surgery. In their study, they gave 50 Gy/25 fractions to the whole breast and 10 Gy/5 fractions to the boost area to the patients who underwent sequential IMRT, and they gave a total of 50.4 Gy/28 fractions to the whole breast for patients who were applied SIB IMRT while, at the same time, they gave an additional dose of 60 Gy/28 fractions to the boost volume. In their study, in the administration of the SIB-IMRT technique and the sequential IMRT technique to the same side lung; the comparison of the mean doses of V5 value for 10 patients revealed no statistically significant results, while the comparison of the mean dose values for V20 value in 10 patients revealed a statistical significance. They demonstrated that with the SIB-IMRT technique, treatment could be performed with a lower dose at V20 in the ipsilateral lung. They stated that the SIB-IMRT technique might be suitable for standard use in breast-conserving RT to reduce irradiated excess normal tissue volumes and to reduce the dose in organs at risk. Similar results were obtained in our study, and it has been shown that the SIB technique can be used to reduce the dose of organs at risk.
Study Limitations
There are several limitations in our study. This is a dosimetric study and does not include vital aspects necessary for clinical use. The number of patients used for comparison was limited to 10, which can be expanded in the next study to obtain a better sample.
TARTIŞMA
GBM tümörlerin tedavisinde standart tedavi günümüzde cerrahi, kemoradyoterapi ve adjuvan kemoterapidir13. Yüksek gradlı astrositomlarda tümör dokusu cerrahi yöntemle ne kadar geniş çıkarılmaya çalışılsa da infiltratif yapıları nedeni ile mikroskopik düzeydeki neoplastik hücreler, normal beyin dokusunda tekrar çoğalırlar. Bu nedenle kalıntı hücrelerin çoğalmasını engellemek ya da subtotal rezeksiyondan sonra geride kalan makroskopik tümörü ortadan kaldırmak için RT önerilir14. Malign glial tümörlerin tedavisinde RT önemli bir tedavi seçeneğidir. Bu çalışmada malign glial tümör tanılı 10 olgu için YART ve SIB-YART planları yapılmış, hedef volüm kapsanması, riskli organ dozları ve MU açısından dozimetrik olarak karşılaştırılmıştır.
Fogliata ve ark.15 baş boyun hastalarında YART ve SIB-YART planlarının potansiyel faydalarını planlama açısından ve dozimetrik düzeyde değerlendirmişlerdir. Doz dağılımları, tüm planlar için ters planlama YART ile elde edilmiş ve YART optimizasyon işleminden sonra sliding window tekniği kullanılmıştır. YART tekniği ile elde edilen planlar için fiziksel doz dağılımının ve homojenitenin daha iyi olduğunu belirtmişlerdir. V95 parametresinin SIB planlarında daha düşük olduğunu bulmuşlardır (p=0,002). Spinal kord ve parotis gibi RAO’ların aldığı dozların SIB-YART tekniğinde daha düşük olduğunu belirtmişlerdir. Yapmış olduğumuz çalışmada da benzer şekilde, YART tekniği ile elde edilen planların doz ile kapsanması açısından daha avantajlı olduğu ancak RAO’ların aldığı dozların SIB-YART tekniğinde daha düşük olduğu bulunmuştur.
Li ve ark.16 prostata yüksek doz ve pelvik bölgesine daha düşük doz vermek için YART ve SIB-YART planlarını karşılaştırmışlardır. SIB-YART tekniğinin, kritik yapıların daha iyi korunması, daha verimli uygulama, daha kısa tedavi süresi ve daha iyi biyolojik etkinlik dahil olmak üzere potansiyel avantaja sahip olduğunu belirtmişlerdir. Bu çalışmaya paralel olarak malign glial tümör tanılı 10 olgu için yapılan bu çalışmada SIB-YART planları YART planları ile karşılaştırıldığında beyin sapı, optik kiazma, optik sinirler ve orbitaların aldıkları ortalama dozların SIB-YART tekniğinde anlamlı olarak düşük olduğu gözlemlenmiştir.
Onal ve ark.17 volumetrik ayarlı ark tedavi (VMAT) ve helikal tomoterapi (HT) tedavisinde sıralı boost tekniği (SEB) ile SIB tekniklerini dozimetrik olarak karşılaştırmışlardır. Yapmış oldukları çalışmada SIB tekniğinin SEB tekniğine göre HT planlarında kalbi daha iyi koruduğunu belirtmişlerdir. Bizim çalışmamız da kritik organların SIB tekniği ile daha iyi korunduğu gözlemlenmiştir.
Farzin ve ark.18 yüksek dereceli gliomaları olan 20 hastada VMAT için SIB ve sıralı boost yöntemini karşılaştırmışlardır. Yaptıkları çalışmada SIB yönteminde, PTV fraksiyon başına 1,8 Gy dozla 30 fraksiyonda 54 Gy alırken, tümör yatağı fraksiyon başına 2 Gy’den 60 Gy almıştır. Elde ettikleri sonuçlara göre her iki tekniğin hedef kapsamı açısından benzer olduğunu ancak SIB tekniğinin kritik organların korunmasında önemli derecede daha üstün olduğunu bulmuşlardır. Bu çalışmadan elde edilen sonuçların yapmış olduğumuz çalışma ile benzer olduğu görülmüştür.
Nageeti ve ark.19 yüksek dereceli glioma tanısı olan 7 olgu için VMAT tekniğinde PTV ve RAO’ların dozimetrik kapsamını SIB ve sıralı boost yöntemi ile karşılaştırmışlardır. Çalışmalarında kritik organların korunmasının tüm planlar için benzer olmasına rağmen, toplam dozun daha az sayıda fraksiyonu ile SIB’nin kullanılmasının, kısa sağkalımı olan hastaların toksisiteyi artırmadan tedavisi için en iyi seçenek olabileceğini belirtmişlerdir. Yapmış olduğumuz çalışmada ise, bu çalışmanın aksine, SIB-YART tekniğinin risk altındaki kritik yapıları koruması nedeniyle YART planlarına göre daha avantajlı olduğu gösterilmiş olup sağlıklı dokuları koruduğu için YART planlarına göre dozimetrik avantaj sağlamıştır.
Çelen ve Kızılkaya20 yapmış oldukları çalışmada, meme koruyucu cerrahi uygulanmış hastalarda tüm meme ve boost alanına sekansiyel YART ve SIB-YART teknikleri ile PTV ve RAO’ların dozimetrik olarak karşılaştırılmasını amaçlamışlardır. Çalışmalarında ardışık YART kullanılan hastalara tüm memeye 50 Gy/25 fraksiyon ve boost alanına 10 Gy/5 fraksiyon, SIB-YART kullanılan hastalara da tüm memeye toplam 50,4 Gy/28 fraksiyon verilirken aynı zamanda boost hacmine ek doz 60 Gy/28 fraksiyon doz vermişlerdir. Yapmış oldukları çalışmada SIB-YART tekniği ile ardışık YART tekniği aynı taraf akciğerde uygulandığında; V5 değerinin 10 hasta için ortalama dozları karşılaştırıldığında sonuçlar istatistiksel olarak anlamlı değilken, V20 değerinin 10 hasta için ortalama doz değerleri karşılaştırıldığında istatiksel olarak anlamlı olduğunu bulmuş, SIB-YART tekniği ile aynı taraf akciğerde V20’de daha düşük doz ile tedavi gerçekleştirilebileceğini ortaya koymuşlardır. Işınlanan fazla normal doku hacimlerini azaltmak ve RAO’da doz azaltımı için SIB-YART tekniğinin, meme koruyucu RT’de standart kullanım için uygun olabileceğini belirtmişlerdir. Yapmış olduğumuz çalışmada da bu çalışmaya benzer sonuçlar elde edilmiş olup, RAO’ların dozunu azaltmak için SIB tekniğinin kullanılabileceği gösterilmektedir.
Çalışmanın Kısıtlılıkları
Yaptığımız çalışmada çeşitli sınırlamalar mevcuttur. Bu bir dozimetrik çalışmadır ve klinik kullanım için gerekli hayati yönleri içermez. Karşılaştırma için kullanılan hasta sayısı 10 ile sınırlıydı, bu daha iyi örneklem elde etmek için bir sonraki çalışmada genişletilebilir.
CONCLUSION
It is known that IMRT therapy has many advantages over conventional RT. IMRT therapy is capable of delivering a highly compatible dose of irradiation to the target while preserving surrounding tissues. In the SIB-IMRT technique, on the other hand, all target volumes can become conformal by using different fraction sizes simultaneously. The SIB-IMRT technique can also be an easier, more effective and error-free IMRT planning and implementation method, because the same plan is used throughout the entire treatment. Studies have shown that the use of SIB-IMRT provides dosimetric advantages due to shorter treatment time, potential radiobiological gains, and preservation of normal tissues.


